Introduction

This page provides work instructions on how to setup the Keller Econoline General Purpose Transmitter powered by the Element-C.


Materials

  • Element-C 
  • Keller Econoline General Purpose Transmitter


Equipment

  • Small flathead screwdriver


Procedure

  1. Carefully remove the contents from its packaging.  If any of the contents looks damaged, please send a picture of the contents to help@elementalmachines.com. 
  2. Plug in the Element-C and complete the Wifi Connect instructions
  3. Slightly loosen the screws in SLOTS 1, 2, and 9 on the green terminal block on the Element-C.
  4. Insert the WHITE wire of the Keller Econoline cable into SLOT 1 of the green terminal block on the Element-C. Tighten the screw to ensure that the wire is secure in the slot.
  5. Insert the DRAIN/CASE Wire of the Keller Econoline cable into SLOT 2 of the green terminal block on the Element-C. Tighten the screw to ensure that the wire is secure in the slot.
  6. Insert the BLACK Wire of the Keller Econoline cable into SLOT 9 of the green terminal block on the Element-C. Tighten the screw to ensure that the wire is secure in the slot.

Figures 1a (top): Keller Econoline Pressure Transmitter Wire.  Figure 1b (bottom) Wiring of Keller Econoline Pressure Transmitter into Element-C