Introduction
This page provides work instructions on how to setup the Keller Econoline General Purpose Transmitter powered by the Element-C.
Materials
- Element-C
- Keller Econoline General Purpose Transmitter
Equipment
- Small flathead screwdriver
Procedure
- Carefully remove the contents from its packaging. If any of the contents looks damaged, please send a picture of the contents to help@elementalmachines.com.
- Plug in the Element-C and complete the Wifi Connect instructions.
- Slightly loosen the screws in SLOTS 1, 2, and 9 on the green terminal block on the Element-C.
- Insert the WHITE wire of the Keller Econoline cable into SLOT 1 of the green terminal block on the Element-C. Tighten the screw to ensure that the wire is secure in the slot.
- Insert the DRAIN/CASE Wire of the Keller Econoline cable into SLOT 2 of the green terminal block on the Element-C. Tighten the screw to ensure that the wire is secure in the slot.
- Insert the BLACK Wire of the Keller Econoline cable into SLOT 9 of the green terminal block on the Element-C. Tighten the screw to ensure that the wire is secure in the slot.
Figures 1a (top): Keller Econoline Pressure Transmitter Wire. Figure 1b (bottom) Wiring of Keller Econoline Pressure Transmitter into Element-C